Collar Tie Calculator

Upper-Third Height, Tie Length, End Cuts, Spacing and Nails for Rafter Collar Ties

As an Amazon Associate I earn from qualifying purchases.

Collar ties join opposing rafters high in the attic. The 2021 IRC (R802.4.6) puts them in the upper third of the attic space, requires at least a 1 × 4 nominal board and spaces them no more than 4 ft on centre; Table R602.3(1) calls for 3-10d common or 4-10d box nails at each end. The ridge rises (width ÷ 2) × pitch ÷ 12 above the wall plate, so the lowest tie the code allows is two-thirds of the way up, and because each rafter climbs in a straight line the tie there is one-third of the building width. Enter the width, pitch and, if you like, your own tie height, roof length and rafter spacing, and the Collar Tie Calculator returns the ridge height, the lowest allowed tie height, the tie length and end cut, which rafter pairs get a tie and the nails. On a 24 ft wide house at 6/12 the ridge is 6 ft up, collar ties go at least 4 ft above the plate and are 8 ft long; a 40 ft roof with rafters at 16 in needs 11 ties.

Collar ties are horizontal boards that join opposing rafters high in the attic, mainly to hold the roof together at the ridge under wind uplift. The 2021 IRC (R802.4.6) puts them in the upper third of the attic space, requires at least 1 × 4 nominal lumber and spaces them no more than 4 ft on centre; 2021 IRC Table R602.3(1) calls for 3-10d common, 4-10d box or 4-3 in × 0.131 in face nails at each end. Rafter ties in the lower third (R802.5.2) are a separate requirement.

Lowest allowed collar tie and its length

Ridge height above the plate, lowest tie height (upper third) and tie length there
WidthPitchRidge heightLowest tieTie length
24 ft4/124 ft 0 in2 ft 8 in8 ft 0 in
24 ft6/126 ft 0 in4 ft 0 in8 ft 0 in
24 ft8/128 ft 0 in5 ft 4 in8 ft 0 in
24 ft12/1212 ft 0 in8 ft 0 in8 ft 0 in
28 ft6/127 ft 0 in4 ft 8 in9 ft 4 in
28 ft8/129 ft 4 in6 ft 2.69 in9 ft 4 in
32 ft6/128 ft 0 in5 ft 4 in10 ft 8 in
32 ft10/1213 ft 4 in8 ft 10.69 in10 ft 8 in

Worked example: 24 ft wide, 6/12, 40 ft long, rafters at 16 in

Frequently asked questions

Where do collar ties go?

In the upper third of the attic space, measured from the wall plate up to the ridge. The 2021 IRC (R802.4.6) requires it. On a 24 ft wide house at 6/12 the ridge is 6 ft above the plate, so collar ties go no lower than 4 ft above it.

How far apart should collar ties be?

No more than 4 ft on centre under IRC R802.4.6 — every third rafter pair at 16 in centres, every second pair at 24 in centres. A 40 ft roof with rafters at 16 in has 31 pairs and needs 11 collar ties.

What size lumber for collar ties?

At least 1 × 4 nominal under IRC R802.4.6. Many framers use 2 × 4 or 2 × 6 because they nail better and double as a ceiling frame, but the code minimum is a 1 × 4.

How do you nail collar ties?

Face nail each end to the rafter with 3-10d common (3 in × 0.148 in), 4-10d box (3 in × 0.128 in) or 4-3 in × 0.131 in nails, per 2021 IRC Table R602.3(1). A 1 1/4 in 20-gauge ridge strap is the listed alternative.

What is the difference between collar ties and rafter ties?

Collar ties sit in the upper third and mainly keep the rafters together at the ridge under wind uplift. Rafter ties (or ceiling joists) sit in the lower third, near the plates, and stop the rafters pushing the walls apart (IRC R802.5.2). Collar ties do not replace rafter ties — raising ties to get a vaulted ceiling needs a structural ridge beam.