Impact Resistant Shingles Explained

UL 2218 Classes, Insurance Credits and When to Upgrade

As an Amazon Associate I earn from qualifying purchases.

Impact resistant shingles are products that have passed the UL 2218 steel ball test without cracking the mat, and Class 4 — a two inch ball dropped twice on the same spot — is the top rating in the series and the one insurers recognise. Most achieve it with polymer modified SBS asphalt that flexes and rebounds instead of fracturing, sometimes with a reinforcing scrim laminated to the back, which also makes them heavier per square and more forgiving in cold weather and under foot traffic. This guide explains all four impact classes and exactly what the test does not cover, how the construction differs from standard architectural shingles, and the three questions to ask your carrier before choosing a product: whether they credit a Class 4 roof, how much, and what documentation they need. It closes with a table of situations where the upgrade is a strong case and where standard architectural shingle is enough.

Impact-resistant shingles are rated by a standardised steel-ball drop test, UL 2218, on a scale of Class 1 to Class 4. Class 4 is the top rating and it is the one insurers recognise.

What the rating means

UL 2218 impact classes
ClassSteel ball dropMeaning
Class 11.25 in ballLowest rating
Class 21.5 in ball
Class 31.75 in ball
Class 42 in ballHighest — no cracking on the back of the shingle

The test drops the ball twice on the same spot from 20 feet and the shingle passes if there is no cracking on the reverse. It is a laboratory test of one failure mode — it is not a guarantee against hail damage.

When they are worth it

What they do not do

Claiming the discount

Insurers want documentation: the product, its UL 2218 Class 4 certification, and the installation invoice. Get all three from the contractor at the time and send them to the insurer rather than assuming the discount applies automatically — it usually does not.

Short answer: A shingle passes UL 2218 Class 4 when two hits from a 2-inch steel ball dropped 20 feet onto the same spot leave no crack or split. The class is printed on the bundle wrapper and the product data sheet — Owens Corning TruDefinition Duration FLEX and Duration STORM, for example, are both sold as UL 2218 Class 4.

Which shingles pass the UL 2218 test?

There is no single list to look up on the roof — the rating belongs to a specific product line, and one brand family can include both rated and unrated shingles. Check it this way before you sign a quote:

  1. Ask the contractor for the exact product line, not just the brand (for example “TruDefinition Duration FLEX”, not “Owens Corning”).
  2. Open that product’s data sheet and look for “UL 2218 Class 4” (or Class 3). If the sheet does not state a class, treat the shingle as unrated.
  3. Check the bundle wrappers on delivery day: the impact class is printed on them, and they are what your insurer will ask you to photograph.
  4. Keep the data sheet, a wrapper photo and the invoice naming the product. Insurers that credit a Class 4 roof usually want that paperwork.

Source: Roofing Contractor, “Owens Corning Roofing Expands Availability of TruDefinition Duration FLEX, Duration STORM Shingles”.

UL 2218 test: ball size and drop height by class

UL 2218 impact classes — steel ball dropped twice on the same spot
ClassSteel ballDrop heightPasses when
Class 11.25 in12 ftNo crack or split after the impacts
Class 21.5 in15 ftNo crack or split after the impacts
Class 31.75 in17 ftNo crack or split after the impacts
Class 42 in20 ftNo crack or split after two hits on the same spot

Dents and granule scuffs are allowed; cracking through the shingle is not. The hail damage calculator compares a storm’s hail size with these ball sizes.

Source: UL 2218 class summaries published by Black Hill Roofing and CeDUR (the standard itself is sold by UL).

Related: Hail damage roof calculator · Roof insurance claim guide

Class 4 shingles cost per square: work out your own premium

This site’s 2026 band for standard architectural shingles is $450–$650 per square installed. The Class 4 premium on top of that depends on the product line and your supplier, so price it from your own quotes:

  1. Ask each contractor to price the same roof twice — the standard line and the Class 4 line — as separate line items.
  2. Subtract to get the premium per square, then multiply by your roof’s squares (roof area ÷ 100).
  3. Ask your insurer for the yearly credit on a documented Class 4 roof.
  4. Divide the upgrade cost by the yearly credit for the payback in years.
Worked example: 25-square roof (example premiums and credits, not quotes)
Premium per squareUpgrade on 25 squaresPayback at $200/yr creditPayback at $400/yr credit
$50$1,2506.3 years3.1 years
$100$2,50012.5 years6.3 years
$150$3,75018.8 years9.4 years

A payback shorter than the 25–30 year life of an architectural shingle roof means the credit alone covers the upgrade.

Related: Asphalt shingle roof cost calculator · Shingles calculator

Frequently asked questions

Which shingles pass the UL 2218 test?

Only product lines whose data sheet states a UL 2218 class. Owens Corning TruDefinition Duration FLEX and Duration STORM are both sold as UL 2218 Class 4. Check the exact line on the data sheet and the bundle wrapper, because one brand family can include unrated shingles.

What is the drop height for each UL 2218 class?

Class 1 uses a 1.25-inch steel ball from 12 feet, Class 2 a 1.5-inch ball from 15 feet, Class 3 a 1.75-inch ball from 17 feet and Class 4 a 2-inch ball from 20 feet. The shingle passes if it does not crack or split.

How much more do Class 4 shingles cost per square?

Get the standard and Class 4 lines priced as separate line items and subtract. Standard architectural shingles run $450–$650 per square installed on this site’s 2026 band; a $100-per-square premium adds $2,500 to a 25-square roof.

What are impact resistant shingles?

They are shingles that have passed the UL 2218 steel-ball impact test without cracking the mat. Most achieve it with a polymer-modified (SBS) asphalt that stays flexible instead of shattering, or with a reinforcing mesh on the back. Class 4 is the top rating in the series and the one insurers usually recognise.

What does Class 4 mean on a shingle?

Class 4 is the highest UL 2218 impact classification. In the test a two-inch steel ball is dropped twice on the same spot from twenty feet, and the shingle passes only if the mat does not crack or split. It is a laboratory rating, not a guarantee against hail damage — very large or wind-driven hail can still damage a Class 4 roof.

Do impact resistant shingles lower insurance premiums?

Many carriers offer a discount for a documented Class 4 roof, and in hail-prone states some make it a condition of favourable roof coverage. The size of any discount is set by the carrier and the state, so ask yours directly what they credit and what documentation they need. Keep the manufacturer’s product certification and your installer’s invoice on file.

Are impact resistant shingles worth the extra cost?

The case is strongest where hail is frequent: a longer service life, fewer claim cycles, and often a premium credit that offsets some of the upfront difference. Where hail is rare, the extra cost buys mainly durability and wind performance rather than a financial return. Ask your carrier for the credit first — that number is what tips the calculation.

How are impact resistant shingles different from regular shingles?

The asphalt is modified with polymers so the shingle flexes and rebounds instead of fracturing, and some products add a reinforcing scrim on the back. They are usually heavier per square, sometimes need a slightly different fastening pattern, and stay pliable at lower temperatures — which is also why they handle wind and foot traffic better.

Do impact resistant shingles look different?

Not meaningfully. Class 4 products come in the same architectural and designer profiles and the same colour ranges as standard lines, so the roof looks like any other quality shingle roof. The difference is in the mat and the asphalt, not the appearance.

Can Class 4 shingles still be damaged by hail?

Yes. The rating means the mat survived a specific standardised impact, not that the roof is hail-proof. Large stones, wind-driven hail striking at an angle, and repeated storms all still cause damage — including granule loss and bruising that an adjuster will assess the same way as on any other roof.

Picking a colour in an impact-rated line? See how to choose shingle colour.

Check what the maker actually covers before you pay the premium; the roofing warranty guide explains material and workmanship cover.

Considering a Class 4 metal roof instead? The stone-coated steel roof cost calculator prices it at $7–$13 per sq ft installed.

Class 4 lines often pack 4 bundles to the square. Check how many bundles of shingles in a square for the line you pick.