Roof heat cable does not stop ice dams from forming; it keeps drainage channels open through the ice so meltwater can escape instead of backing up under the shingles. It is a fix for the symptom, and it works best alongside the real cure — insulation and ventilation that keep the roof deck cold.
This guide compares the two cable types and the parts that go with them, works out a cable length for a typical eave, and covers the electrical requirements. For the causes of ice dams, see our ice dam prevention guide.
Pros and cons describe each type from its specifications; this is not a hands-on product test. As an Amazon Associate we earn from qualifying purchases.
Best for: Homeowners fitting one problem eave with a plug-in kit. Check: Kit length from the maker's eave chart, and the listing (UL or ETL) for roof use.
Pros
Cons
Best for: Long eaves, gutters and downspouts, and permanent installations. Check: Watts per foot and the termination kit it needs.
Pros
Cons
Best for: Fixing cable in the zigzag pattern without piercing shingles. Check: Clip style made for your shingles or metal roof.
Pros
Cons
Best for: Switching cable on only in freezing weather. Check: Outdoor rating and the maximum amps it switches.
Pros
Cons
Every manufacturer publishes a chart, and it is the figure to follow, because the zigzag spacing depends on the overhang depth. As a planning figure, the zigzag over the eave uses about 2 to 3 feet of cable per foot of eave, plus one run along the gutter and a loop down and back up each downspout.
Worked example: A 40 ft eave with 2 downspouts
About 180 ft — round up to the next kit size, and confirm against the manufacturer's chart for your overhang.
Eave length is the same measurement the drip edge calculator and gutter calculator start from.
Ice dams form when heat escaping from the house melts snow high on the roof and it refreezes over the cold overhang. Air sealing, attic insulation and balanced ventilation stop the melt; ice and water membrane at the eaves stops leaks when a dam forms anyway. Size the membrane with the ice and water shield calculator and check your venting with the attic ventilation calculator.
It keeps channels open through ice so meltwater can drain, which prevents many ice-dam leaks. It does not stop ice from forming, and it works best combined with better attic insulation and ventilation.
Follow the manufacturer's chart for your overhang. As a rough guide, the zigzag uses 2 to 3 feet of cable per foot of eave, plus the gutter length and a loop down each downspout — about 180 ft for a 40 ft eave with two 10 ft downspouts.
You can, but it wastes electricity. A thermostat controller switches it on only near freezing, and self-regulating cable reduces its own output as it warms.
Only self-regulating cable, and only with the manufacturer's end-seal kit. Constant-wattage kits are a fixed length and must not be cut.
Yes. The US electrical code requires ground-fault protection for outdoor de-icing and snow-melting equipment, and manufacturers require it too.