How to Install a Roof Ridge Vent

Slot Cut, Vent Placement & Ridge Cap

As an Amazon Associate I earn from qualifying purchases.

This guide walks you through installing a continuous ridge vent for balanced attic ventilation. Cut a 1.5-2 inch slot along each side of the ridge (leaving 6 inches at each end uncut), set the ridge vent product over the slot, fasten with the included nails into the rafters, and cap with hip-and-ridge cap shingles. The ridge vent must be paired with adequate soffit intake (NFA matched 50/50) for the system to actually pull air through the attic. Pair with our Vents Calculator.

A ridge vent is the exhaust half of an attic ventilation system. It works by letting hot air leave at the highest point of the roof while cooler air is drawn in at the soffits — which means it only works if the soffits are open.

Before you start — check the intake

This is the step people skip and it is the reason most ridge vents disappoint. Go into the attic with a torch and look along the eaves. If insulation has been pushed into the eave and closed off the soffit vents, the ridge vent will have nothing to draw from and the attic will stay hot. Fit baffles in each rafter bay to hold the insulation back and restore the path first.

Intake area should at least match exhaust area. More exhaust than intake makes a ridge vent draw air in at one end and out at the other, or pull conditioned air up out of the house through ceiling gaps.

Cutting the slot

Fitting the vent

Common mistakes

Frequently asked questions

How wide should the ridge vent slot be?

Commonly 2 inches total, cut as 1 inch each side of the ridge centre, but follow the vent manufacturer instructions — products differ and the slot width is what their net free area rating assumes.

Can I install a ridge vent without soffit vents?

You can fit it, but it will not work. A ridge vent is exhaust and it needs matching intake at the eaves to draw from. Without soffit intake it either does nothing or pulls conditioned air up out of the house.

Should I remove old box vents when adding a ridge vent?

Yes, on the same roof plane. Leaving them in short-circuits the system — the ridge vent starts drawing air in through the nearest box vent instead of up from the soffits.

How far from the end of the ridge should the slot stop?

About 6 inches at each end, and short of any hip, chimney or wall. That leaves solid deck for the end plugs to seal against so wind-driven rain cannot enter at the ends.

Choosing a ridge vent? See our roof vent buying guide for net free area and weather baffles.

Rather have it installed? The roof vent installation cost calculator shows what a ridge vent costs with a roofer.