As an Amazon Associate I earn from qualifying purchases.
#3 bars at 15 in on center each way or #4 at 18 in. That meets the ACI 318-19 shrinkage and temperature minimum of 0.0018 × the slab section (0.0864 sq in per foot for 4 in) and its 18 in maximum spacing. A 6 in slab takes #3 at 10 in or #4 at 18 in.
Rebar in a slab mainly holds shrinkage and temperature cracks tight, and ACI 318-19 sets the minimum for that steel at 0.0018 times the slab's cross-section, with bars no more than five times the thickness or 18 inches apart, whichever is less. For a 4 inch slab that is 0.0864 square inches of steel per foot of width: #3 bars (0.11 sq in) at 15 inches on center each way, or #4 bars (0.20 sq in) at the 18 inch maximum. A 5 inch slab takes #3 at 12 inches or #4 at 18; a 6 inch slab #3 at 10 inches or #4 at 18; an 8 inch slab #4 at 13 inches or #5 at 18. Keep bars 3 inches from the edges and the ground, and support them so they stay between the middle and the upper third of the slab during the pour, as the 2021 IRC (R506.2.4) requires. The IRC does not require rebar in a residential slab-on-ground at all, and a plan or engineer's spacing always overrides this minimum. Enter your slab to get the spacing, bars, sticks and weight.
Short answer: a 4 in slab takes #3 bars at 15 in on center each way or #4 at 18 in; a 6 in slab #3 at 10 in or #4 at 18 in. These meet the ACI 318-19 shrinkage and temperature minimum (0.0018 × the slab section, §24.4.3.2) and its maximum spacing, the lesser of 5 × thickness and 18 in (§24.4.3.3). The IRC does not require rebar in a residential slab-on-ground; plans override this minimum.
| Slab | Steel needed | #3 spacing | #4 spacing | #5 spacing |
|---|---|---|---|---|
| 4 in | 0.0864 sq in/ft | 15 in | 18 in | 18 in |
| 5 in | 0.1080 sq in/ft | 12 in | 18 in | 18 in |
| 6 in | 0.1296 sq in/ft | 10 in | 18 in | 18 in |
| 8 in | 0.1728 sq in/ft | 7 in | 13 in | 18 in |
6×6 W1.4×W1.4 welded wire mesh carries 0.028 sq in of steel per foot, about a third of the 0.0864 sq in a 4 in slab needs to meet the ACI ratio. It keeps hairline cracks tight but is not equal to a rebar grid.
To meet the ACI 318-19 shrinkage and temperature minimum (0.0018 × the slab's cross-section, 0.0864 sq in per foot for 4 in), #3 bars go at 15 in on center each way or #4 bars at 18 in, the maximum spacing allowed. That is why #4 at 18 in each way is a common patio and driveway specification.
A 6 in slab needs 0.1296 sq in of steel per foot: #3 at 10 in, or #4 or #5 at 18 in on center each way (the 18 in cap governs).
ACI 318-19 §24.4.3.3 limits shrinkage and temperature bars to the lesser of five times the slab thickness and 18 in. For any slab 4 in or thicker that means 18 in on center; for a 3.5 in slab it is 17.5 in.
ACI 318-19 §25.2.1 sets the minimum clear gap between parallel bars at the greatest of 1 in, one bar diameter and 4/3 of the largest aggregate. With 3/4 in stone that is 1 in clear for #3–#8 bars, so the minimum hardly ever limits a slab.
The 2021 IRC (R506.2.4) requires bars in a slab-on-ground to stay between the center and the upper third of the slab during the pour. Set them on chairs or concrete dobies; bars laid on the ground and pulled up with a rake usually end up at the bottom, where they do little.
No. Common 6×6 W1.4×W1.4 mesh has 0.028 sq in of steel per foot, about a third of the 0.0864 sq in a 4 in slab needs to meet the ACI ratio. Mesh helps hold shrinkage cracks tight; it is not a substitute for a rebar grid where one is specified.
The IRC does not require reinforcement in a residential slab-on-ground, but rebar keeps cracks from opening and the slabs either side from moving apart. A 4–5 in driveway with #4 at 18 in each way, on a compacted base with control joints every 8–12 ft (10–15 ft at 5 in), is a common specification; check your local code and HOA.
Bar sizes and weights: the rebar size chart.
Need the whole roof at once? The free roofing calculator works out roof area, squares, shingle bundles, underlayment, drip edge, ridge cap and installed cost from one set of measurements.