What R-value does roof insulation need?

R-49 is the common target for the roof or ceiling in cold and mixed climates. That is about 20 inches of blown fibreglass, 15 inches of blown cellulose, 16 inches of fibreglass batt or about 8 inches of closed-cell spray foam. Air seal the ceiling plane before adding any of it.

How these calculators work and where the figures come from

Enter your attic footprint and what's already up there. This works out the extra depth needed to reach your target R-value, how many bags or batts that takes, and what it should cost.

Worked example

With these inputs:

ResultValue
Additional depth to add20 in
Target R-valueR-60
Existing R-valueR-10
Bags required34 bags
Estimated material cost$1,428
Installed cost (pro)$2,448

Formula

Existing R = existing depth × R-per-inch of what's up there · R needed = target R − existing R · Depth to add = R needed ÷ R-per-inch of new material · Bags = (R needed × area) ÷ bag coverage rating, then add waste

Frequently asked questions

Can I add new insulation over old insulation?

Yes, as long as the old material is dry and not mouldy. Never lay faced (paper or foil backed) batts over existing insulation — the facing traps moisture. Use unfaced batts or blown-in.

How many inches is R-49?

About 19–20 inches of blown fiberglass (at R-2.5 per inch), about 14 inches of cellulose, or 13 inches of high-density batts. Loose-fill bags list a coverage chart on the side — follow it.

Can I add new insulation on top of old?

Usually yes, and it is the cheapest upgrade available. Blown-in or unfaced batts go straight over existing material. The one thing not to do is lay faced batts on top of existing insulation with the facing down, because that puts a vapour retarder in the middle of the assembly where moisture can collect against it. Use unfaced material when topping up.

How deep should attic insulation be?

Divide your target R-value by the material's R per inch. At R-49 that is roughly 13.5–14 inches of cellulose or about 19.5 inches of blown fibreglass — the difference is why the same target produces very different depths. Mark the depth on a rafter before you start so you can see when you have reached it.

Should I cover the attic hatch and recessed lights?

The hatch yes, with a rigid box or a purpose-made cover, because an uninsulated hatch is a large hole in the middle of the ceiling. Recessed lights need care: only IC-rated fixtures may be covered, and anything not rated for contact needs a clearance kept around it. Burying a non-IC fixture is a genuine fire risk, not a code technicality.